PLC4X MODBUS
![]()
Description​
The Modbus adapter allows to connect to a PLC using the Modbus specification.
Configuration​
The following configuration options are available when creating the adapter:
PLC Address​
The IP address of the Modbus device without any prefix, which will be added automatically when creating the adapter.
PLC Port​
The PLC port refers to the port of the PLC, such as 502.
Node ID​
The Node ID refers to the ID of the specific device.
Nodes​
The Nodes section requires configuration options for the individual nodes.
Nodes can be either imported from a comma-separated CSV file, or can be directly assigned in the configuration menu.
The following fields must be provided for each node:
- Runtime Name: Refers to the field to internally identify the node, e.g., in the data explorer or pipeline editor.
- Node Address: Refers to the address of the Node in Modbus, e.g., 1
- Object Type: Can be selected from the available options
DiscreteInput,Coil,InputRegister, orHoldingRegister.
An example CSV file looks as follows:
Runtime Name,Node Address,Object Type,
field1,1,Coil
temperature,2,Coil
Note that the CSV header must exactly match the titles Runtime Name, Node Address and Object Type.